Digital Color Corrector UFM-100DCC |
 |
 |
This is a modular type of color corrector that can be installed in a UF frame. It supports analog composite or SD-SDI input and output signals. A broad spectrum of functions ranging from the color correction of signals to various clip functions are available.
Analog composite or SD-SDI input and output signals supported
A-to-D or D-to-A conversion function also available
Varied color correction functions (Balanced, Differential and Sepia modes)
Process amplifier functions provided (video level, chroma level, chroma phase, setup level)
Gamma adjustment functions (independent adjustment of G, B and R signals, high/mid/dark tone adjustment)
Function for dividing the screen into sections to make it easier to compare and check the images before and after correction
Control of up to four units enabled using the DCC-OU remote control unit (option)
* The DCC-OU is required to control the parameters.
| Specifications |
| Standard |
525/60 (NTSC), 625/50 (PAL) (Auto detect)
|
| Video Input |
Analog composite: 1.0Vp-p or SD-SDI: 270Mbps, 75Ω, 1ea., BNC |
| Video Output |
Analog composite: 1.0Vp-p or SD-SDI: 270Mbps, 75Ω, 2ea., BNC |
| Process Control |
Video Level: 50% - 150%*1
|
Y Level: 50% - 150%*1
|
C Level: 50% - 150%*1
|
HUE: -30° - +30°*1
|
Setup Level: -15% - +15%*1
|
Y White Clip: 50% - 109%*1
|
C White Clip: 50% - 111%*1
|
| Y Black Clip: -7% - 109% |
| Color Correction |
BAL: GBR adjust*1 |
| DIF: Color adjust*1 |
SEPIA: Chroma level HUE adjust*1
|
White Level (GBR): 50% - 150% (for Input signal)*1
|
Black Level (GBR): 50% - 150% (for Input signal)*1
|
| Gamma Level (GBR): 75% - 125% (for Input signal)*1 |
| Interface |
REMOTE: RS-422, 1ea., 9-pin D-sub (male)
|
| Temperature / Humidity |
10ºC - 40ºC / 30% - 90% (no condensation) |
| Power / Consumption / Draw |
Supply from UF frame, +12VDC - +24VDC / 12W / +12VDC: 1.0A, +24VDC: 0.5A |
| Dimensions / Weight |
106 (W) x 303 (D) mm (Front board), 108.5 (W) x 83.3 (D) mm (Rear board) / Approx. 0.5kg |
| Require Slot |
2 slot |
| Accessories |
Operation manual
|
| Option |
DCC-OU: Remote control unit |
*1: All parameters can be set only DCC-OU (option).
|