| Specifications |
|
| Video Format |
NTSC or PAL (Auto detect) |
| Video Input |
Analog composite: 1.0 Vp-p (asynchronous acceptable, B/W), 75Ω or loopthrough (automatic termination), BNC x 9 |
| Video Output |
Analog composite: 1.0 Vp-p ±0.1 V, 75Ω BNC x 2 (Full screen or split screen) |
| Spot Output |
Analog composite: 1.0 Vp-p ±0.1 V, 75Ω BNC x 2 (Full screen) |
| Interfaces |
REMOTE: 25-pin D-sub (female) x 1
- Remote input: TTL negative logic pulses or make contact
- Time correction input: TTL negative logic pulses or make contact |
ALARM: 25-pin D-sub (female) x 1
- Alarm input: TTL negative logic pulses or level signals or make contact
- Alarm output: Relay make contact, output x 1, Max +24 V DC 100 mA
*Menus to allow external alarm, video loss detection and fan alarm to be selected |
| RS-232C: 9-pin D-sub (male) x 1, Operations from external devices and menu settings enabled by communication function |
| Ethernet: 10BASE-T/100BASE-TX, RJ-45 |
| Display Modes |
4 (A/B) / 5+1 (A/B) / 9 (A/B) |
| Automatic Switching |
Time from 0 to 30 seconds can be set for each channel on one screen |
| Time from 1 to 30 seconds can be set for each split-display screen consisting of split frames |
| Video Loss Detection |
Detection of video loss possible for each channel; loss alarm time can be set from 1 to 60 seconds |
| Character Display |
Camera title: 1 line x 8 characters consisting of alphanumerics, symbols |
| Time/date display: Year/month/day, hours/minutes/seconds (24-hour display), accuracy within ±10 sec. per month |
| Special Display |
Alarm display: Automatic switching to alarm screen with an upper-case letter "A" |
| Video loss display: Automatic switching to video loss screen with an upper-case letter "L" |
| Screen-dividing frames |
White, black or none selected |
| Data Backup |
Date and menu settings, etc. (using lithium battery) |
| Temperature / Humidity |
0ºC to 40ºC / 30% to 90% (no condensation) |
| Power |
100 V AC to 240 V AC, 50/60 Hz |
| Consumption |
28 VA (27 W) at 100 V AC, 33 VA (26 W) at 200 V AC |
| Dimensions / Weight |
424 (W) x 44 (H) x 350 (D) mm, EIA1RU / 4.5kg |
| Accessories |
Remote control software: Windows 2000 Professional (Service Pack 4 or higher),
Windows XP Professional / Home Edition (Service Pack 1 or higher)
Operation manual, Rack mount brackets, AC cord |