| Specifications |
|
| Standard |
NTSC or PAL (Auto detect)
|
| Video Input |
Analog composite: 1.0Vp-p (asynchronous acceptable, B/W), 75Ω or loopthrough (automatic termination), 9ea., BNC |
| Monitor Output |
Analog composite: 1.0Vp-p ±0.1V, 75Ω, 2ea., BNC, (Full screen view or split screen view)
|
| Spot Output |
Analog composite: 1.0Vp-p ±0.1V, 75Ω, 2ea., BNC (Full screen view)
* Switching noise will occur during channel switching since the signals are asynchronous.
|
| Interfaces |
Remote input: TTL negative logic pulses or make contact
|
Alarm input: TTL negative logic pulses or level signals or make contact
|
Time correction input: TTL negative logic pulses or make contact
|
Alarm output: Relay make contact output x 1
*Menus to allow external alarm, video loss detection and fan alarm to be selected
|
RS-232C: Operations from external devices and menu settings enabled by communication function
|
Ethernet: RJ-45 connector
|
| Display Modes |
4 (A/B) / 5+1 (A/B) / 9 (A/B) |
| Automatic Switching Functions |
Time from 0 to 30 seconds can be set for each channel on one screen |
Time from 1 to 30 seconds can be set for each split-display screen consists of split frames
|
| Video Loss Detection |
Detection of video loss possible for each channel; loss alarm time can be set from 1 to 60 seconds
|
| Character Display |
Camera title: 1 line x 8 characters consisting of alphanumerics, symbols, Kana
|
| Time/date display: Year/month/day, hours/minutes/seconds (24-hour display), monthly error within ±10 sec. |
| Special Display |
Alarm display: Automatic switching to alarm screen and display of upper-case letter A |
| Video loss display: Automatic switching to video loss screen and display of upper-case letter L |
| Screen-dividing frames |
White, black or none selected |
| Setting data retention |
Date and menu settings, etc. (using lithium battery) |
| Temperature / Humidity |
0ºC - 40ºC/30% - 90% (no condensation)
|
| Power / Consumption |
100VAC - 240VAC, 50/60Hz / Approx. 28VA (27W) at 100VAC, Approx. 33VA (26W) at 200VAC |
| Dimensions / Weight |
424 (W) x 44 (H) x 350 (D) mm, EIA 1RU / Approx. 4.5kg |
| Accessories |
Remote control software: Windows2000 Professional (Service Pack 4 or higher), Windows XP Professional / Home Edition (Service Pack 1 or higher)
Rack mount brackets, Operation Manual, AC cord |