Frame Synchronizer & TBC FA-115 |
 |
 |
FA-115 is a low cost Time Base Corrector / Frame Synchronizer with Noise Reducer and cable compensator, which is specifically designed for CATV, ITV and CCTV applications.
 |
Analog composite video input / output standard. |
 |
Full frame memory to prevent picture field inversion during processing. |
 |
Low cost and compact TBC / Synchronizer with noise reducer and cable compensator. |
 |
Composite Input / Output for easy integration into current available system. |
 |
Digital recursive motion adaptive noise reducer for improving the picture quality. |
 |
Internal 4:2:2 Component processing and Digital Encoder/Decoder ensure high quality and stable signal output. |
| Specifications |
|
| Video Format |
NTSC or PAL (Auto detect) |
| Video Input |
Analog composite: 1.0 Vp-p, 75Ω BNC x 1 |
Genlock Input |
BB: NTSC: 0.429 Vp-p/PAL: 0.45 Vp-p, 75Ω BNC x 1, loop-through (Terminate with 75Ω terminator, if unused.) |
| Video Output |
Analog composite: 1.0 Vp-p, 75Ω BNC x 2 |
| Signal Processing |
4:2:2 component |
| Correction Range |
2 fields (field inversion prevented) |
| Sampling Frequency |
Y: 13.5 MHz, C: 6.75 MHz |
| Quantization |
8-bit |
| Frequency Response |
100 kHz - 4.2 MHz: -0.5 dB - +0.5 dB, 4.2 MHz - 5.0 MHz: -1.0 dB - +1.0 dB, roll off above 5.0 MHz (NTSC) |
| 100 kHz - 5.0 MHz: -0.5 dB - +0.5 dB, 5.0 MHz - 5.5 MHz: -1.0 dB - +1.0 dB, roll off above 5.5 MHz (PAL) |
S/N Ratio |
56 dB (no quantization noise) |
| DG/DP |
2% |
| K-Factor (2T Pulse) |
Less than 2% |
| H/V Tilt |
Less than 1% |
| Residual Jitter |
Y: ±15 ns, C: ±2º |
| Proc Amp |
Video Level: -3 dB to +3 dB
Chroma Level: -3 dB to +3 dB
Setup Level: 0 IRE to +15 IRE
Chroma Phase: -30º to +30º |
| Genlock Phase Control* |
H Phase: -2 ?s to +2 ?s |
| Interfaces |
Remote: BNC x 1 (Freeze control, make contact) |
| Temperature / Humidity |
10ºC to 40ºC / 30% to 90% (no condensation) |
| Power / Consumption |
100 V AC to 240 V AC ±10%, 50/60 Hz / 18 VA (10 W) at 100 V AC |
| Dimensions / Weight |
212 (W) x 44 (H) x 350 (D) mm / 2.5 kg |
| Accessories |
Operation manual, AC cord |
| Options |
Single mount or dual mount rack brackets |
*No SC Phase control is available with FA-115. FA-125, FA-128 or FA-147 is required for SC Phase control. |